A new concept for the evaluation of flowmeter dynamic response is presented. A technique based on hydraulic line dynamics is applied to achieve accurate measurements of the reference flowrate. The major components in the equipment used in experimental verification of the theory were a test pipe, a pulsating flow generator, three pressure transducers, an A/D converter, and a microcomputer system. This equipment allowed the dynamic characteristics of a flowmeter to be investigated in both the time and frequency domains. Comparisons of flowrates measured using the line dynamic technique and the same flowrates recorded by the flowmeter are presented. The results confirm the feasibility and practicability of the dynamic line technique for measuring rapidly varying flows.
Skip Nav Destination
Article navigation
June 1997
Technical Briefs
A Dynamic Evaluation Technique for Liquid Flow Meters Based on Hydraulic Line Dynamics
Guangzheng Peng,
Guangzheng Peng
Department of Automatic Control, Beijing Institute of Technology, Beijing, People’s Republic of China
Search for other works by this author on:
Tong Zhao
Tong Zhao
Department of Automatic Control, Beijing Institute of Technology, Beijing, People’s Republic of China
Search for other works by this author on:
Guangzheng Peng
Department of Automatic Control, Beijing Institute of Technology, Beijing, People’s Republic of China
Tong Zhao
Department of Automatic Control, Beijing Institute of Technology, Beijing, People’s Republic of China
J. Dyn. Sys., Meas., Control. Jun 1997, 119(2): 305-307 (3 pages)
Published Online: June 1, 1997
Article history
Received:
March 20, 1992
Revised:
October 11, 1995
Online:
December 3, 2007
Citation
Peng, G., and Zhao, T. (June 1, 1997). "A Dynamic Evaluation Technique for Liquid Flow Meters Based on Hydraulic Line Dynamics." ASME. J. Dyn. Sys., Meas., Control. June 1997; 119(2): 305–307. https://doi.org/10.1115/1.2801252
Download citation file:
12
Views
Get Email Alerts
Cited By
An Adaptive Sliding-Mode Observer-Based Fuzzy PI Control Method for Temperature Control of Laser Soldering Process
J. Dyn. Sys., Meas., Control
Fault detection of automotive engine system based on Canonical Variate Analysis combined with Bhattacharyya Distance
J. Dyn. Sys., Meas., Control
Multi Combustor Turbine Engine Acceleration Process Control Law Design
J. Dyn. Sys., Meas., Control (July 2025)
Related Articles
Nonlinear Vibrations
of an Extensible Flexible Marine Riser Carrying a Pulsatile
Flow
J. Appl. Mech (July,2007)
Theoretical, Numerical, and Experimental Study of the Time of Flight Flowmeter
J. Fluids Eng (April,2011)
The Design of a New Flow Meter for Pipes Based on the Drag Force Exerted on a Cylinder in Cross Flow (Drag Force Flow Meter: DFFM)
J. Fluids Eng (July,2004)
A Universal, Nonintrusive Method for Correcting the Reading of a Flow Meter in Pipe Flow Disturbed by Installation Effects
J. Fluids Eng (September,2002)
Related Proceedings Papers
Related Chapters
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach
Occlusion Identification and Relief within Branched Structures
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling
Threshold Functions
Closed-Cycle Gas Turbines: Operating Experience and Future Potential