Double-row discrete-hole cooling arrangements offer several advantages over single-row systems yet the detailed cooling mechanism is less completely understood than for the single-row. This is partly because there have been fewer studies of this geometry and partly because the flow structure is more complex. The present paper presents detailed flow-field and concentration measurements around the injection holes for double-row injection on a flat plate at 30 deg to the mainstream. The experiments span values of the blowing injection mass velocities from 0.25 to 1.0 times the free stream mass velocity and for two boundary layer thicknesses just upstream of the injection. In contrast to single-row injection the cooling effectiveness rise monotonically with M over the range studied. Computer simulation of these flows and similar experiments of [7] has been made using a three-dimensional finite-difference code that embodies a semi-elliptic treatment of the flow field in the neighborhood of the injection holes in conjunction with a two-equation turbulence model with non-isotropic effective transport coefficients. It emerged from the calculations, that, for injection velocities up to 50 percent of the free stream value, levels of film-cooling effectiveness are extremely well predicted beyond about 10 diameters behind the leading row of holes. Around the holes themselves, however, there are certain discrepancies which become more serious as the injection level is raised.
Skip Nav Destination
Article navigation
April 1980
This article was originally published in
Journal of Engineering for Power
Research Papers
Double-Row Discrete-Hole Cooling: an Experimental and Numerical Study
G. Bergeles,
G. Bergeles
National Technical University, Athens, Greece
Search for other works by this author on:
A. D. Gosman,
A. D. Gosman
Imperial College, London, England
Search for other works by this author on:
B. E. Launder
B. E. Launder
Department of Mechanical Engineering, University of California, Davis, CA 95616
Search for other works by this author on:
G. Bergeles
National Technical University, Athens, Greece
A. D. Gosman
Imperial College, London, England
B. E. Launder
Department of Mechanical Engineering, University of California, Davis, CA 95616
J. Eng. Power. Apr 1980, 102(2): 498-503 (6 pages)
Published Online: April 1, 1980
Article history
Received:
March 13, 1979
Online:
September 28, 2009
Citation
Bergeles, G., Gosman, A. D., and Launder, B. E. (April 1, 1980). "Double-Row Discrete-Hole Cooling: an Experimental and Numerical Study." ASME. J. Eng. Power. April 1980; 102(2): 498–503. https://doi.org/10.1115/1.3230284
Download citation file:
Get Email Alerts
Cited By
Inter-Stage Pressure Drop of Multi-Stage Brush Seal with Differentiated Structure
J. Eng. Gas Turbines Power
Mixture Distribution in Spark Ignited Port Fuel Injection Engines: A Review.
J. Eng. Gas Turbines Power
Experimental Investigation of Combustion Dynamics in a High-Pressure Liquid-fueled Swirl Combustor
J. Eng. Gas Turbines Power
Related Articles
Increasing Adiabatic Film-Cooling Effectiveness by Using an Upstream Ramp
J. Heat Transfer (April,2007)
Investigation on the Effect of a Realistic Flow Field on the Adiabatic Effectiveness of an Effusion-Cooled Combustor
J. Eng. Gas Turbines Power (May,2015)
High-Resolution Measurements of Local Effectiveness From Discrete Hole Film Cooling
J. Turbomach (October,2001)
Experimental Study of Effusion Cooling With Pressure-Sensitive Paint
J. Eng. Gas Turbines Power (May,2017)
Related Chapters
Boundary Layer Analysis
Centrifugal Compressors: A Strategy for Aerodynamic Design and Analysis
Introduction
Design and Analysis of Centrifugal Compressors
Extended Surfaces
Thermal Management of Microelectronic Equipment