Abstract

Multiple pre-cleaned, four-room residential containments were each subjected to a single high-dust generating activity involving lead-based paint. After dust generation, a geometric wipe sampling grid was used, with a target of 8 interior and 8 perimeter samples in each room, to assess dust-lead on the floors. The containment was then cleaned using the “High Efficiency Particulate Air (HEPA) vacuum/3-bucket wet-mop/HEPA vacuum” procedure found in the U.S. Dept. of Housing and Urban Development Guidelines. Post-cleaning (clearance) floor wipe samples were then taken at side-by-side locations to the pre-cleaning samples. It was found that: [1] floor dust-lead along the perimeters of rooms was three times more difficult to clean than dust-lead from the interiors of the rooms; [2] post-cleaning dust-lead loadings tended to be higher along the perimeters of the rooms than in the interiors of the rooms such that clearance failure was much more likely for individual floor samples collected along the perimeters; and [3] four-wipe composite sampling within each room (two randomly selected from the perimeter and two randomly selected from the interior) provided a very reliable method for detecting clearance failure (99% or greater) versus a randomly selected single wipe sample per room (50% or less).

References

1.
Title 24, Code of Federal Regulations, Part 35-Lead-Based Paint Poisoning Prevention in Certain Residential Structures.
2.
Title 40, Code of Federal Regulations, Part 745-Lead-Based Paint Poisoning Prevention in Certain Residential Structures.
3.
Standard Specification for Wipe Sampling Materials for Lead in Surface Dust
,” ASTM E1792-03.
4.
U.S. Dept. of Housing and Urban Development, “
Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing
,” Washington, DC, June
1995
as amended.
5.
Standard Practice for Collection of Settled Dust Samples Using Wipe Sampling Methods for Subsequent Lead Determination
,” ASTM E1728-03.
6.
Standard Practice for Ultrasonic Extraction of Paint, Dust, Soil, and Air Samples for Subsequent Determination of Lead
,” ASTM E1979-04.
7.
Standard Test Method for Determination of Lead by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), Flame Atomic Absorption Spectrometry (FAAS), or Graphite Furnace Atomic Absorption Spectrometry (GFAAS) Techniques
,” ASTM E1613-04.
8.
U.S. Environmental Protection Agency, “
EPA National Lead Laboratory Accreditation Program Laboratory Quality System Requirements
,” Rev. 3.0, Washington, DC (July 5,
2007
).
9.
American Industrial Hygiene Association (AIHA) Proficiency Analytical Testing Programs (PATP), LLC, 2700 Prosperity Ave., Fairfax, VA.
This content is only available via PDF.
You do not currently have access to this content.