Abstract

This article describes a Synchronous reference frame based current control scheme for three phase shunt active power filters (SAPFs) to reduce or to remove harmonics, correct power factor, and balance asymmetrical load is analyzed. This active power filter (APFs) is used to compensate harmonic currents and reactive power generated from the nonlinear loads. In this article, to determine reference compensation currents under balanced source voltages, the voltage source inverter for harmonic filtering of a three phase shunt active filter is used. In this proposed method, a fuzzy gain scheduling controller is used and the response of the DC link voltage is compared with PI controller during transient and steady state. The main objective of this article is to analyze shunt active filters with fuzzy gain scheduling controllers and PI controllers. To carry out this analysis, active and reactive current methods (Id–Iq) are considered. Extensive simulations were carried out. The simulations were performed under balance sinusoidal conditions. The results validate the dynamic behavior of a fuzzy gain scheduling controller over PI controllers. The simulation of the proposed system is evaluated using MATLAB Simulink and the results show that the proposed method is more effective than the existing methods.

References

1.
Jintakosonwit
,
P.
,
Fujita
,
H.
, and
Akagi
,
H.
, “
Control and Performance of a Fully-Digital-Controlled Shunt Active Filter for Installation on a Power Distribution System
,”
IEEE Trans. Power Electron.
, Vol.
17
,
2002
, pp.
132
140
.
2.
Gao
,
D.
,
Lu
,
Q.
, and
Sun
,
X.
, “
Design and Performance of an Active Power Filter for Unbalanced Loads
,”
Proceedings of Power System Technology Conference 2002
, Vol.
4
, Oct 13–17,
2002
, pp.
2496
2500
.
3.
Akagi
,
H.
, “
New Trends in Active Filters for Power Conditioning
,”
IEEE Trans. Ind. Appl.
, Vol.
32
, No.
6
,
1996
, pp.
1312
1322
.
4.
Zhang
,
C.
,
Chen
,
Q.
,
Zhao
,
Y.
,
Li
,
D.
, and
Xiong
,
Y.
, “
A Novel Active Power Filter for High-Voltage Power Distribution Systems Application
,”
IEEE Trans. Power Delivery
, Vol.
22
, No.
2
,
2007
, pp.
911
918
.
5.
Li
,
H.
,
Zhuo
,
F.
,
Wang
,
Z.
,
Lei
,
W.
, and
Wu
,
L.
, “
A Novel Time-Domain Current-Detection Algorithm for Shunt Active Power Filters
,”
IEEE Trans. Power System
, Vol.
17
, No.
2
,
2005
, pp.
644
651
.
6.
Zheng
,
F. P.
, “
Application Issues of Active Power Filters
,”
IEEE Trans. Ind. Appl.
, Vol.
4
, No.
5
,
1998
, pp.
21
30
.
7.
Dugan
,
R. C.
,
McGranaghan
,
M. F.
, and
Beaty
,
H. W.
,
Electrical Power Systems Quality
,
McGraw-Hill
,
New York
,
1996
.
8.
Murat
,
K.
and
Özdemir
,
E.
, “
Harmonic and Reactive Power Compensation With Shunt Active Power Filter Under Non-Ideal Mains Voltage
,”
Electric Power Syst. Res.
, Vol.
74
,
2005
, pp.
363
370
.
9.
Nabae
,
A.
,
Satoshi
,
O.
, and
Hirofumi
,
Akagi.
, “
A Novel Control Scheme for Current-Controlled PWM Inverters
,”
IEEE Trans. Ind. Appl.
, Vol.
1A-22
, No.
4
,
1986
, pp.
562
570
.
10.
Brod
,
D. M.
and
Novotny
,
D. M.
, “
Current Control of VSI–PWM Inverter
,”
IEEE Trans. Ind. Appl.
, Vol.
21
,
1985
, pp.
562
570
.
11.
Zeng
,
J.
,
Yu
,
C.
,
Qi
,
Q.
,
Yan
,
Z.
,
Ni
,
Y.
,
Zhang
,
B. L
,
Chen
,
S.
, and
Wu
,
F. F.
, “
A Novel Hysteresis Current Control for Active Power Filter With Constant Frequency
,”
Electr. Power Syst. Res.
, Vol.
68
,
2004
, pp.
75
82
.
12.
Jain
,
S. K.
,
Agrawal
,
P.
, and
Gupta
,
H. O.
, “
Fuzzy Logic Controlled Shunt Active Power Filter for Power Quality Improvement
,”
Proc. Inst. Electr. Eng. Electr. Power Appl.
, Vol.
149
, No.
5
,
2002
, pp.
317
328
.
13.
Liu
,
S.
, “
An Adaptive Kalman Filter for Dynamic Estimation of Harmonic Signals
,”
Proceedings of the 8th International Conference on Harmonics Quality Power
,
Athens, Greece
, Oct 14–16,
1998
, pp.
286
292
.
14.
Grady
,
W. M.
,
Samotj
,
M. J.
, and
Noyola
,
A. H.
, “
Survey of Active Power Line Conditioning Methodologies
,”
IEEE Trans. Power Deliv.
, Vol.
5
, No.
3
,
1990
, pp.
1536
1542
.
15.
Moran
,
L. A.
,
Dixon
,
J. W.
, and
Wallace
,
R. R.
, “
A Three-Phase Active Power Filter Operating With Fixed Switching Frequency for Reactive Power and Current Harmonic Compensation
,”
IEEE Trans. Ind. Electron.
, Vol.
42
, No.
4
,
1995
, pp.
402
408
.
16.
Akagi
,
H.
,
Kanazawa
,
Y.
, and
Nabae
,
A.
, “
Generalized Theory of the Instantaneous Reactive Power in Three-Phase Circuits
,”
Proceedings of the IEEJ International Power Electronics Conference
,
Tokyo, Japan
, March 27–31,
1983
, pp.
1375
1386
.
17.
Akagi
,
H.
,
Yoshihira
,
K.
, and
Nabae
,
A.
,“
Instantaneous Reactive Power Compensators Comprising Switching Devices Without Energy Storage Components
,”
IEEE Trans. Ind. Appl.
, Vol.
20
, No.
2
,
1984
, pp.
625
630
.
18.
Willems
,
J. L.
, “
A New Interpretation of the Akagi-Nabae Power Components for Nonsinusoidal Three-Phase Situations
,”
IEEE Trans. Instrum. Meas.
, Vol.
41
, No.
4
,
1992
, pp.
5523
5297
.
19.
Suresh
,
M.
and
Panda
,
A. K.
, “
PI and Fuzzy Logic Controller Based 3-Phase 4-Wire Shunt Active Filters for the Mitigation of Current Harmonics with the Id-I Qcontrol Strategy
,”
J. Power Electron.
, Vol.
11
, No.
6
,
2011
, pp.
914
921
20.
Peng
,
F. Z.
and
Lai
,
J. S.
, “
Generalized Instantaneous Reactive Power Theory for Three-Phase Power Systems
,”
IEEE Trans. Instrum. Meas.
, Vol.
45
, No.
1
,
1996
, pp.
293
297
.
21.
Girgis
,
A. A.
,
Chang
,
W. B.
, and
Makram
,
E. B.
, “
A Digital Recursive Measurement Scheme for On-Line Tracking of Power System Harmonics
,”
IEEE Trans. Power Deliv.
, Vol.
3
,
1991
, pp.
1153
1160
.
22.
EI-Habrouk
,
M.
and
Darwish
,
M. K.
, “
Design and Implementation of a Modified Fourier Analysis Harmonic Current Computation Technique for Power Active Filters Using DSPs
,”
Proc. Inst. Electr. Eng. Electr. Power Appl.
, Vol.
148
, No.
1
,
2001
, pp.
21
28
.
This content is only available via PDF.
You do not currently have access to this content.