Abstract

This study aimed to investigate the radiation absorption effects of the humeral locking plate system on breast tissue in different radiological energy ranges using MCNPX (Monte Carlo N-Particle Extended Transport Code System, version 2.6.0) general-purpose Monte Carlo code. In the present study, a novel MCNPX simulation setup has been generated considering the elemental mass fractions of investigated materials and biological structures. The validation of MCNPX simulation geometry used in this study has been provided by comparing the results with standard XCOM data for mass attenuation coefficients of Ti-6Al-4V alloy. A very good match between XCOM and MCNPX data has been achieved. Therefore, validated simulation input has been employed for further investigations of the present study. Our findings showed that the amount of absorbed energy that was measured in breast tissue with the humeral locking plate was higher than that without humeral locking plate for the same radiological energy value. Our results would be beneficial to use the present simulation technique and mass attenuation coefficients for radiation physics and medical applications, especially for assessments of breast cancer risk.

References

1.
Karaismailoğlu
T. N.
,
Gülman
B.
,
Şen
S.
, and
Çıray
M.
, “
Erişkin Humerus Cisim Kırıklarında Tedavi
,”
Journal of Experimental and Clinical Medicine
9
, no. 
2
(
1992
):
131
136
.
2.
Sarmiento
A.
,
Kinman
P. B.
,
Galvin
E. G.
,
Schmitt
R. H.
, and
Phillips
J. G.
, “
Functional Bracing of Fractures of the Shaft of the Humerus
,”
Journal of Bone and Joint Surgery, American
59
, no. 
5
(July
1977
):
596
601
, https://doi.org/10.2106/00004623-197759050-00004
3.
Sarmiento
A.
,
Zagorski
J.
,
Zych
G.
,
Latta
L.
, and
Capps
C.
, “
Functional Bracing for the Treatment of Fractures of the Humeral Diaphysis
,”
Journal of Bone and Joint Surgery, American
82
, no. 
4
(April
2000
):
478
486
, https://doi.org/10.2106/00004623-200004000-00003
4.
Spiguel
A. R.
and
Steffner
R. J.
, “
Humeral Shaft Fractures
,”
Current Reviews in Musculoskeletal Medicine
5
, no. 
3
(September
2012
):
177
183
, https://doi.org/10.1007/s12178-012-9125-z
5.
Ertem
K.
,
Esenkaya
İ.
,
İnan
M.
,
Taş
F.
, and
Bora
A.
, “
Humerus Cisim Kırıklarında Tedavi Yöntemleri
,”
İnönü Üniversitesi Tıp Fakültesi Dergisi
11
, no. 
1
(
2004
):
15
17
.
6.
Idoine
,
J. D.
 III
,
French
B. G.
,
Opalek
J. M.
, and
DeMott
L.
, “
Plating of Acute Humeral Diaphyseal Fractures through an Anterior Approach in Multiple Trauma Patients
,”
Journal of Orthopaedic Trauma
26
, no. 
1
(January
2012
):
9
18
, https://doi.org/10.1097/BOT.0b013e318214ebd5
7.
Bhandari
M.
,
Devereaux
P. J.
,
Mckee
M. D.
, and
Schemitsch
E. H.
, “
Compression Plating versus Intramedullary Nailing of Humeral Shaft Fractures—A Meta-Analysis
,”
Acta Orthopaedica
77
, no. 
2
(
2009
):
279
284
, https://doi.org/10.1080/17453670610046037
8.
Beyaz
S.
and
Cınar
B. M.
, “
Humerus Üst Uç Kırıklarında İnternal Fiksasyon
,”
Turkiye Klinikleri Journal of Orthopaedics and Traumatology-Special Topics
10
, no. 
3
(
2017
):
243
248
.
9.
Brenner
D. J.
and
Hall
E. J.
, “
Computed Tomography—An Increasing Source of Radiation Exposure
,”
New England Journal of Medicine
 357 (
2007
):
2277
2284
, https://doi.org/10.1056/NEJMra072149
10.
Brenner
D. J.
,
Doll
R.
,
Goodhead
D. T.
,
Hall
E. J.
,
Land
C. E.
,
Little
J. B.
,
Lubin
J. H.
, et al., “
Cancer Risks Attributable to Low Doses of Ionizing Radiation: Assessing What We Really Know
,”
Proceedings of the National Academy of Sciences of the United States of America
100
(November
2011
):
13761
13766
, https://doi.org/10.1073/pnas.2235592100
11.
Brenner
D. J.
,
Elliston
C. D.
,
Hall
E. J.
, and
Berdon
W. E.
, “
Estimates of the Cancer Risks from Pediatric CT Radiation Are Not Merely Theoretical: Comment on ‘Point/Counterpoint: In X-Ray Computed Tomography, Technique Factors Should Be Selected Appropriate to Patient Size. Against the Proposition,’ by W. Huda, S. C. Bushong, and W. R. Hendee, Published in Medical Physics 28, no. 8 (August 2001): 1543–1545
,”
Medical Physics
28
, no. 
11
(November
2001
):
2387
2388
, https://doi.org/10.1118/1.1415074
12.
Gholamkar
L.
,
Mowlavi
A. A.
,
Sadeghi
M.
, and
Athari
M.
, “
Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code
,”
Iranian Journal of Radiology
13
, no. 
4
(October
2016
): e36484, https://doi.org/10.5812/iranjradiol.36484
13.
Tekin
H. O.
,
Erguzel
T. T.
,
Sayyed
M. I.
,
Singh
V. P.
,
Manici
T.
,
Altunsoy
E. E.
, and
Agar
O.
, “
An Investigation on Shielding Properties of Different Granite Samples Using MCNPX Code
,”
Digest Journal of Nanomaterials and Biostructures
13
, no. 
2
(April–June
2018
):
381
389
.
14.
Disegi
J. A.
, “
Titanium Alloys for Fracture Fixation Implants
,”
Injury
31
, suppl.
4
(December
2000
):
D14
D17
, https://doi.org/10.1016/S0020-1383(00)80017-0
15.
Wu
C.
,
Ramaswamy
Y.
,
Gale
D.
,
Yang
W.
,
Xiao
K.
,
Zhang
L.
,
Yin
Y.
, and
Zreiqat
H.
, “
Novel Sphene Coatings on Ti–6Al–4V for Orthopedic Implants Using Sol–Gel Method
,”
Acta Biomaterialia
4
, no. 
3
(May
2008
):
569
576
, https://doi.org/10.1016/j.actbio.2007.11.005
16.
Steinemann
S. G.
and
Perren
S. M.
. Surgical implant and alloy for use in making an implant. U.S. Patent 4,040,129, filed July 24, 1973, and issued August 9,
1977
.
17.
Radiation Safety Information Computational Center
RSICC Computer Code Collection MCNPX Version 2.4.0, Monte Carlo N-Particle Transport Code System for Multiple and High Energy Applications, Report CCC-715
(
Oak Ridge, TN
:
Oak Ridge National Laboratory
,
2002
).
18.
Tekin
H. O.
, “
MCNP-X Monte Carlo Code Application for Mass Attenuation Coefficients of Concrete at Different Energies by Modeling 3×3 Inch NaI(Tl) Detector and Comparison with XCOM and Monte Carlo Data
,”
Science and Technology of Nuclear Installations
2016
(
2016
): 6547318, https://doi.org/10.1155/2016/6547318
19.
Akkurt
İ.
,
Tekin
H. O.
, and
Mesbahi
A.
, “
Calculation of Detection Efficiency for the Gamma Detector Using MCNPX
,”
Acta Physica Polonica A
128
, no. 
2-B
(
2015
):
332
334
, https://doi.org/10.12693/APhysPolA.128.B-332
20.
Tekin
H. O.
,
Singh
V. P.
,
Kara
U.
,
Manıcı
T.
, and
Altunsoy
E. E.
, “
Investigation of Nanoparticle Effect on Radiation Shielding Property Using Monte Carlo Method
,”
Celal Bayar University Journal of Science
12
, no. 
2
(
2016
):
195
199
, https://doi.org/10.18466/cbujos.15586
21.
Tekin
H. O.
,
Manici
T.
, and
Singh
V. P.
, “
An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation
,”
Politeknik Dergisi
19
, no. 
4
(
2016
):
617
622
.
22.
Tekin
H. O.
,
Singh
V. P.
, and
Manici
T.
, “
Effects of Micro-Sized and Nano-Sized WO3 on Mass Attenuation Coefficients of Concrete by Using MCNPX Code
,”
Applied Radiation and Isotopes
121
(March
2017
):
122
125
, https://doi.org/10.1016/j.apradiso.2016.12.040
23.
Tekin
H. O.
and
Manici
T.
, “
Simulations of Mass Attenuation Coefficients for Shielding Materials Using the MCNP-X Code
,”
Nuclear Science and Techniques
28
(July
2017
): 95, https://doi.org/10.1007/s41365-017-0253-4
24.
Tekin
H. O.
,
Singh
V. P.
,
Altunsoy
E. E.
,
Manici
T.
, and
Sayyed
M. I.
, “
Mass Attenuation Coefficients of Human Body Organs Using MCNPX Monte Carlo Code
,”
Iranian Journal of Medical Physics
14
, no. 
4
(November–December
2017
):
229
240
, https://doi.org/10.22038/IJMP.2017.23478.1230
25.
Tekin
H. O.
,
Singh
V. P.
,
Manici
T.
, and
Altunsoy
E. E.
, “
Validation of MCNPX with Experimental Results of Mass Attenuation Coefficients for Cement, Gypsum and Mixture
,”
Journal of Radiation Protection and Research
42
, no. 
3
(September
2017
):
154
157
, https://doi.org/10.14407/jrpr.2017.42.3.154
26.
Dong
M. G.
,
El-Mallawany
R.
,
Sayyed
M. I.
, and
Tekin
H. O.
, “
Shielding Properties of 80TeO2–5TiO2–(15–x) WO3–xAnOm Glasses Using WinXCom and MCNP5 Code
,”
Radiation Physics and Chemistry
141
(December
2017
):
172
178
, https://doi.org/10.1016/j.radphyschem.2017.07.006
27.
Lakshminarayana
G.
,
Baki
S. O.
,
Kaky
K. M.
,
Sayyed
M. I.
,
Tekin
H. O.
,
Lira
A.
,
Kityk
I. V.
, and
Mahdi
M. A.
, “
Investigation of Structural, Thermal Properties and Shielding Parameters for Multicomponent Borate Glasses for Gamma and Neutron Radiation Shielding Applications
,”
Journal of Non-Crystalline Solids
471
(September
2017
):
222
237
, https://doi.org/10.1016/j.jnoncrysol.2017.06.001
28.
Tekin
H. O.
,
Sayyed
M. I.
,
Altunsoy
E. E.
, and
Manici
T.
, “
Shielding Properties and Effects of WO3 and PbO on Mass Attenuation Coefficients by Using MCNPX Code
,”
Digest Journal of Nanomaterials and Biostructures
12
, no. 
3
(July–September
2017
):
861
867
.
29.
Tekin
H. O.
,
Sayyed
M. I.
,
Manici
T.
, and
Altunsoy
E. E.
, “
Photon Shielding Characterizations of Bismuth Modified Borate–Silicate–Tellurite Glasses Using MCNPX Monte Carlo Code
,”
Materials Chemistry and Physics
211
(June
2018
):
9
16
, https://doi.org/10.1016/j.matchemphys.2018.02.009
30.
Kim
S.-C.
,
Kim
H.-Y.
,
Lee
S.-J.
, and
Kim
C.-M.
, “
Influence of Surface Treatment on the Insertion Pattern of Self-Drilling Orthodontic Mini-Implants
,”
Korean Journal of Orthodontics
41
, no. 
4
(August
2011
):
268
279
, https://doi.org/10.4041/kjod.2011.41.4.268
31.
Duck
F. A.
,
Physical Properties of Tissues: A Comprehensive Reference Book
(
London
:
Academic Press
,
1990
).
32.
International Commission on Radiation Units and Measurements
Photon, Electron, Proton and Neutron Interaction Data for Body Tissues, ICRU Report 46
(Bethesda,
MD
:
International Commission on Radiation Units and Measurements
,
1992
).
33.
Singh
A.
,
Nagar
M.
, and
Kumar
A.
, “
An Anthropometric Study of the Humerus in Adults
,”
Research and Reviews: Journal of Medical and Health Sciences
3
, no. 
3
(July–September
2014
):
77
82
.
34.
Weiss
L. W.
and
Clark
F. C.
, “
Three Protocols for Measuring Subcutaneous Fat Thickness on the Upper Extremities
,”
European Journal of Applied Physiology and Occupational Physiology
56
, no. 
2
(March
1987
):
217
221
, https://doi.org/10.1007/BF00640647
35.
Karakasli
A.
,
Basci
O.
,
Ertem
F.
,
Sekik
E.
, and
Havitcioglu
H.
, “
Dual Plating for Fixation of Humeral Shaft Fractures: A Mechanical Comparison of Various Combinations of Plate Lengths
,”
Acta Orthopaedica et Traumatologica Turcica
50
, no. 
4
(August
2016
):
432
436
, https://doi.org/10.1016/j.aott.2016.07.002
36.
More
C. V.
,
Lokhande
R. M.
, and
Pawar
P. P.
, “
Effective Atomic Number and Electron Density of Amino Acids within the Energy Range of 0.122–1.330 MeV
,”
Radiation Physics and Chemistry
125
(August
2016
):
14
20
, https://doi.org/10.1016/j.radphyschem.2016.02.024
This content is only available via PDF.
You do not currently have access to this content.