Abstract

The global increase in refrigeration and air conditioning applications poses a severe problem as regards the environmental degradation caused by greenhouse gas emissions. This study introduces a novel approach wherein both evaporative cooling and passive cooling are integrated to unveil notable enhancements in energy and exergy compared to conventional air conditioning systems. Therefore, this work aims to enhance the thermal performance of a 1.5-ton split air conditioner (SAC) employing outdoor (condenser) evaporative and indoor passive cooling (EPC). The heat removal capacity of a condenser and SAC performance are greatly affected by the air temperature at the condenser inlet. Evaporative cooling serves to lower outdoor air temperature, while passive cooling minimizes the indoor cooling load. Design parameters encompass outdoor temperature (Ta = 30–44 °C), relative humidity (RH = 20–80%), and temperature reduction due to passive cooling (ΔTR = 0.5–5 °C). A model is developed to calculate the temperature reductions of outdoor air through evaporative cooling in diverse climatic conditions, while the range of passive cooling degrees is obtained from previous experiments. Results indicate a substantial enhancement in the thermodynamic performance of the proposed system. The maximum coefficient of performance (COP) improvement of 68.66% is achieved at 44 °C outside temperature and 20% relative humidity. Annual energy savings, under extreme operating conditions, range from 358.4 kWh to 2116.8 kWh. The EPC SAC is identified as more sustainable than the conventional split air conditioner (CSAC). Moreover, the projected system is anticipated to recoup its costs within a relatively short period of 1.42 years.

Graphical Abstract Figure
Graphical Abstract Figure
Close modal

References

1.
Nethaji
,
N.
,
Mohideen
,
T.
, and
Nethaji
,
M.
,
2019
, “
Energy Conservation in Room Air Conditioner Unit by Recovering Cold Energy From Condensate
,”
Int. J. Refrig.
,
104
, pp.
95
102
.
2.
Catrini
,
P.
,
Piacentino
,
A.
,
Cardona
,
F.
, and
Ciulla
,
G.
,
2020
, “
Exergoeconomic Analysis as Support in Decision-Making for the Design and Operation of Multiple Chiller Systems in Air Conditioning Applications
,”
Energy Convers. Manag.
,
220
, p.
113051
.
3.
Sami Missaoui
,
B. C.
,
Driss
,
Z.
, and
Slama
,
R. B.
,
2022
, “
Experimental and Numerical Analysis of a Helical Coil Heat Exchanger for Domestic Refrigerator and Water Heating
,”
Int. J. Refrig.
,
133
, pp.
276
288
.
4.
Sami Missaoui
,
B. C.
,
Driss
,
Z.
, and
Slama
,
R. B.
,
2021
, “
Numerical Analysis of the Heat Pump Water Heater With Immersed Helically Coiled Tubes
,”
J. Energy Storage
,
39
, p.
102547
.
5.
Dai
,
N.
, and
Li
,
S.
,
2018
, “
Simulation and Performance Analysis on Condenser Coil in Household Heat Pump Water Heater
,”
Sustain. Cities Soc.
,
36
, pp.
176
184
.
6.
Yang
,
H.
,
Pei
,
N.
,
Fan
,
M.
,
Liu
,
L.
, and
Wang
,
D.
,
2021
, “
Experimental Study on an Air-Cooled Air Conditioning Unit With Spray Evaporative Cooling System Étude Expérimentale d ‘ une Unité de Conditionnement d ‘ air à Condenseur à air Avec Système de Refroidissement évaporatif par Aspersion
,”
Int. J. Refrig.
,
131
, pp.
645
656
.
7.
Yang
,
H.
,
Pei
,
N.
,
Liu
,
L.
,
Fan
,
M.
, and
Qin
,
Y.
,
2021
, “
Experimental Study on the Effect of Condensate Water on the Performance of Split Air Conditioning System
,”
Energy Rep.
,
7
, pp.
840
851
.
8.
Al-badri
,
A. R.
, and
Al-waaly
,
A. A. Y.
,
2017
, “
The Influence of Chilled Water on the Performance of Direct Evaporative Cooling
,”
Energy Build.
,
155
, pp.
143
150
.
9.
Wang
,
T.
,
Sheng
,
C.
, and
Nnanna
,
A. G. A.
,
2014
, “
Experimental Investigation of Air Conditioning System Using Evaporative Cooling Condenser
,”
Energy Build.
,
81
, pp.
435
443
.
10.
Sarntichartsak
,
P.
, and
Thepa
,
S.
,
2013
, “
Modeling and Experimental Study on the Performance of an Inverter Air Conditioner Using R-410A with Evaporatively Cooled Condenser
,”
Appl. Therm. Eng.
,
51
(
1–2
), pp.
597
610
.
11.
Ketwong
,
W.
,
Deethayat
,
T.
, and
Kiatsiriroat
,
T.
,
2021
, “
Case Studies in Thermal Engineering Performance Enhancement of Air Conditioner in Hot Climate by Condenser Cooling With Cool Air Generated by Direct Evaporative Cooling
,”
Case Stud. Therm. Eng.
,
26
, p.
101127
.
12.
Atmaca
,
İ.
,
Şenol
,
A.
, and
Çağlar
,
A.
,
2022
, “
Performance Testing and Optimization of a Split-Type Air Conditioner With Evaporatively-Cooled Condenser
,”
Eng. Sci. Technol. Int. J.
,
32
, p.
101064
.
13.
Gupta
,
S. K.
,
Arora
,
B. B.
, and
Arora
,
A.
,
2023
, “
Effect of Evaporative Cooling of Condenser on the Performance of Air Conditioner
,”
Iran. J. Sci. Technol. Trans. Mech. Eng
,
47
, pp.
1661
1677
.
14.
Katiyar
,
M.
, and
Agarwal
,
S.
,
2012
, “
An Overview of Passive Cooling Techniques in Buildings: Design Concepts and Architectural Interventions
,”
Civ. Eng. Archit.
,
55
(
1
), pp.
84
97
.
15.
Bhamare
,
D. K.
,
Rathod
,
M. K.
, and
Banerjee
,
J.
,
2019
, “
Passive Cooling Techniques for Building and Their Applicability in Different Climatic Zones—The State of Art
,”
Energy Build
,
198
, pp.
467
490
.
16.
Kumar
,
R.
,
Garg
,
S. N.
, and
Kaushik
,
S. C.
,
2005
, “
Performance Evaluation of Multi-Passive Solar Applications of a Non Air-Conditioned Building
,”
Int. J. Environ. Technol. Manage.
,
5
(
1
), pp.
60
75
.
17.
Perini
,
K.
,
Bazzocchi
,
F.
,
Croci
,
L.
,
Magliocco
,
A.
, and
Cattaneo
,
E.
,
2017
, “
The Use of Vertical Greening Systems to Reduce the Energy Demand for Air Conditioning. Field Monitoring in Mediterranean Climate
,”
Energy Build.
,
143
, pp.
35
42
.
18.
Jacob
,
T. A.
,
Shah
,
N.
, and
Park
,
W. Y.
,
2021
, “
Evaluation of Hybrid Evaporative-Vapor Compression Air Conditioners for Different Global Climates
,”
Energy Convers. Manag.
,
249
, p.
114841
.
19.
Oropeza-Perez
,
I.
, and
Ostergaard
,
P. A.
,
2014
, “
Energy Saving Potential of Utilizing Natural Ventilation Under Warm Conditions—A Case Study of Mexico
,”
Appl. Energy
,
130
, pp.
20
32
.
20.
Oropeza-perez
,
I.
,
2016
, “
Comparative Economic Assessment of the Energy Performance of Air-Conditioning Within the Mexican Residential Sector
,”
Energy Rep.
,
2
, pp.
147
154
.
21.
Arora
,
C. P.
,
2009
,
Refrigeration and Air Conditioning
, 3rd ed.,
McGraw Hill Education (India) Private Limited
,
New Delhi
.
22.
Wu
,
J. M.
,
Huang
,
X.
, and
Zhang
,
H.
,
2009
, “
Theoretical Analysis on Heat and Mass Transfer in a Direct Evaporative Cooler
,”
Appl. Therm. Eng.
,
29
(
5–6
), pp.
980
984
.
23.
Chauhan
,
S. S.
, and
Rajput
,
S. P. S.
,
2017
, “
Experimental Analysis of an Evaporative–Vapour Compression Based Combined Air Conditioning System for Required Comfort Conditions
,”
Appl. Therm. Eng.
,
115
, pp.
326
336
.
24.
Ankit Sethi
,
E. D. V. B.
,
2010
,
Genetron Properties 1.4.1.
,
Honeywell International, Inc.—Buffalo Research Laboratory
,
Buffalo, NY
, https://www.honeywell-refrigerants.com/europe/genetron-refrigerants-modeling-software-download/
25.
Arora
,
A.
,
Arora
,
B. B.
,
Pathak
,
B. D.
, and
Sachdev
,
H. L.
,
2007
, “
Exergy Analysis of a Vapour Compression Refrigeration System with R-22, R-407C and R-410A
,”
Int. J. Exergy
,
4
(
4
), pp.
441
454
. DOI: 10.1504/IJEX.2007.015083
26.
Rosen
,
M. A.
,
Dincer
,
I.
, and
Kanoglu
,
M.
,
2008
, “
Role of Exergy in Increasing Efficiency and Sustainability and Reducing Environmental Impact
,”
Energy Policy
,
36
(
1
), pp.
128
137
.
27.
BEE Govt. of India
,
2015
, “
Schedule—19
,” Bureau of Energy Efficiency, Govt. of India, New Delhi, India, pp.
1
12
, https://www.beestarlabel.com/content/files/inverter ac schedule final.pdf
28.
Lateef Tarish
,
A.
,
Talib Hamzah
,
M.
, and
Assad Jwad
,
W.
,,
2020
, “
Thermal and Exergy Analysis of Optimal Performance and Refrigerant for an Air Conditioner Split Unit Under Different Iraq Climatic Conditions
,”
Therm. Sci. Eng. Prog.
,
19
, pp.
100595
.
29.
Ramachander
,
J.
,
Gugulothu
,
S. K.
,
Sastry
,
G. R. K.
,
Kumar Panda
,
J.
, and
Surya
,
M. S.
,
2021
, “
Performance and Emission Predictions of a CRDI Engine Powered With Diesel Fuel: A Combined Study of Injection Parameters Variation and Box-Behnken Response Surface Methodology Based Optimization
,”
Fuel
,
290
, p.
120069
.
30.
Khurana
,
H.
,
Majumdar
,
R.
, and
Saha
,
S. K.
,
2022
, “
Response Surface Methodology-Based Prediction Model for Working Fluid Temperature During Stand-Alone Operation of Vertical Cylindrical Thermal Energy Storage Tank
,”
Renewable Energy
,
188
, pp.
619
636
.
31.
Borikar
,
S. A.
,
Gupta
,
M. M.
,
Alazwari
,
M. A.
,
Malwe
,
P. D.
,
Moustafa
,
E. B.
,
Panchal
,
H.
, and
Elsheikh
,
A.
,
2021
, “
Case Studies in Thermal Engineering: A Case Study on Experimental and Statistical Analysis of Energy Consumption of Domestic Refrigerator
,”
Case Stud. Therm. Eng.
,
28
, pp.
101636
.
32.
Ministry of Environment, Forest and Climate Change and Government of India
,
2019
, “India Cooling Action Plan (ICAP): Operationalizing Space Cooling Recommendations, http://ozonecell.nic.in/wp-content/uploads/2021/10/India-Cooling-Action-Plan-Booklet-SP.pdf
You do not currently have access to this content.